Your plant generates thousands of data points every minute.

Most of it never gets looked at.

15 issues found
TimestampMachineTagValueUnitOperator
2026-03-15 06:01:12EXT-ABARREL_TEMP_Z1SENTINEL 999.99CMartinez
2026-03-15 06:03:45EXT-AMELT_PRESS_PSISENTINEL -1PSIMartinez
2026-03-15 06:12:08COOL-AWATER_TEMP_INSENTINEL 999.99CJohnson
2026-03-15 06:30:22EXT-ASCREW_TORQUE_PCTSENTINEL -1%Johnson
2026-03-15 07:15:03QCWALL_THICK_MMSENTINEL 999.99mmDavis
2026-03-15 06:05:30EXT-ADIE_TEMPMISSINGCMartinez
2026-03-15 06:20:11HAUL-ALINE_SPEED_MPMMISSINGm/minJohnson
2026-03-15 06:45:55QCOD_MMMISSINGmmDavis
2026-03-15 06:08:00EXT-ABARREL_TEMP_Z2DUPLICATE 215.3CMartinez
2026-03-15 06:08:00EXT-ABARREL_TEMP_Z2DUPLICATE 215.3CMartinez
2026-03-15 06:10:15QCWALL_THICK_MMWRONG UNIT 0.984inMartinez
2026-03-15 06:25:40QCOD_MMWRONG UNIT 4.724inJohnson
2026-03-15 06:50:18SAW-ACUT_LENGTH_MMWRONG UNIT 78.740inDavis
2026-03-15 06:15:22EXT-ABARREL_TEMP_Z3ENCODING 218.7CGonzález
2026-03-15 06:40:33EXT-ATHROUGHPUT_KGHENCODING 142.5kg/hMüller
2026-03-15 06:02:00EXT-ABARREL_TEMP_Z1 210.5CMartinez
2026-03-15 06:04:00EXT-ABARREL_TEMP_Z2 215.1CMartinez
2026-03-15 06:06:00EXT-ASCREW_RPM 45.2RPMMartinez
2026-03-15 06:09:00COOL-AWATER_FLOW_GPM 12.8GPMMartinez
2026-03-15 06:11:00HAUL-ALINE_SPEED_MPM 3.2m/minJohnson
2026-03-15 06:18:00QCWALL_THICK_MM 25.02mmJohnson
2026-03-15 06:22:00QCOD_MM 120.1mmJohnson
2026-03-15 06:35:00EXT-AMOTOR_AMPS 82.4ADavis
2026-03-15 06:42:00EXT-AHOPPER_LEVEL_PCT 67.3%Davis
2026-03-15 06:55:00PLCGOOD_CT 1247ctDavis

Cleaning it by hand takes hours. Missing it costs more.

Sample NumberWall Thickness (mm)I-MR Control Chart — Wall Thickness
Cpk
0.00

The data has a story. SPC tells it.

SPC Control Chart
OEE
78%Typical
Top Defects (Pareto)
Wall ThinOvalitySurfaceLengthColor
30-Day Trends
OEE
Cpk
PPM
kg/h

From noise to insight. In seconds, not days.

Process Capability Report
March 30, 2026

Control Chart — Wall Thickness (mm)
Summary Statistics
Mean25.007 mm
Cpk0.83
Pp / Ppk0.85 / 0.80
OEE78%
PPM (expected)8,480
GRR12.4%
Recommendations
  • Investigate barrel temperature Zone 1 drift causing the upper outlier at sample 26. Consider PID tuning or heater band inspection.
  • The cluster of high readings (samples 42-44) suggests an assignable cause near UCL. Review material lot changes for that production window.
  • Current Cpk of 0.83 meets the 1.33 minimum. Tighten incoming material spec to push toward 1.67 target.

Your team gets a report they can act on.
Your management gets numbers they can trust.

This is what we build.

Data Integration & Migration

Connect your ERP, MES, SCADA, and spreadsheets into a single clean data pipeline. Stop copying and pasting between systems.

Custom Analytics & Dashboards

SPC, capability studies, DOE analysis, and OEE tracking — built for your specific process, your specific metrics, your specific parts.

Training & Workshops

We build the tools, then teach your team to use them. On-site or remote. Your people own the system after we leave.